Squeaky Hardwood Floors.

Posted on Posted in Projects

 

Squeaky Hardwood Floors?
Or
Squeaky Substrate?

 

The process of inspecting and checking for a squeaky requires two-person two inspect.

 

Identifying the squeaky nosy boards.

Fixed the issue.

All wood floors make noises (or eventually will). It is part of living with a natural, organic product. A product that is hygroscopic and reacts to its ever-changing environment will likely move around throughout its service life and develop some sort of squeak, crackle, or pop. An occasional squeak within any properly installed wood floor system is not abnormal. These noises are not always a direct concern with the installed wood floor as long as the movement accompanying the audible squeak does not affect the performance of the installation. However, the fact that all wood floors make noises does not insinuate that they are supposed to, or that they have been manufactured to make these noises.

Many squeaking and popping noises originate from the subfloor system below the floor. Some of the most common causes of a squeaky floor originating from the subfloor system include poorly nailed subfloor sheathing, missing joist hangers, missing nails, or nails that just miss the joist, improperly installed subfloor sheathing, improper application of subfloor adhesive, and excessive shrinkage of subfloor materials. As wood floor installers, we often do our best to address existing squeaks in wood subfloors, but it is not normally something that the wood flooring professional is responsible for fixing unless we’re otherwise contracted to do so.

One trend we have seen within our industry over the last couple of decades has been the movement toward engineered wood flooring. There are many reasons, but improved stability is one major factor. With improved stability, you would expect fewer squeaking, popping, and crunching complaints. To the contrary, one of the more common issues we have heard of through our technical call center is directly related to squeaking, popping, and crunching noises in installed engineered wood floors.
The following are a few of the more common causes of squeaking, popping, and crunching noises in installed engineered wood floors.

Subfloor Flatness
The NWFA standard for subfloor flatness on a nail-down installation is 1/4″ in 10′ or 3/16″ in 6′. When subfloors are outside of the flatness tolerances, voids are created that allow the flooring to move vertically, resulting in a noisy flooring system.

It is almost always necessary to expect that the subfloor seams will need to be sanded flat as part of Jobsite preparation. When the subfloor seams are not sanded flat, the result is normally a subfloor that is not within tolerance. Subfloors that are not properly scraped or cleaned before installation can also cause similar voids or high spots that can result in a noisy floor system. Dried globs of drywall mud, paint, grout, or other construction materials not adequately removed from the subfloor will also adversely affect the flatness of the substrate and result in a noisy floor.

OSB Subflooring 
As the availability of slow growth plywood fades and economics come into play, builders are moving to OSB for their new construction subfloors. OSB can be a good subflooring option, though different performance levels exist. The wood flooring industry has bemoaned the use of commodity OSB products due to swelling after exposure to the multiple wetting/drying cycles experienced during the build.

We know that swelling can occur with any wood product when exposed to water. In OSB, this swelling can create a decrease in fiber density and degradation of bond strength between the strands, especially at panel edges, causing a reduction in wood flooring fastener retention. The loss of fastener holding can directly impact the performance of otherwise properly installed engineered wood flooring.

Recommended Fasteners
The recommended fasteners used when installing engineered products are normally 18-20 gauge cleats or narrow crown staples anywhere from 1″ to 1 1/2″ in length.

These types of fasteners require a much tighter fastener schedule than the heavier gauge, longer-length fasteners used to install 3/4″ solid and engineered wood flooring. In general, for engineered flooring, fasteners should be placed every 3″-4″ and within 1″-2″ of the ends of each plank (unless otherwise suggested by the flooring manufacturer). The truth is, 1″ fasteners used to install engineered wood flooring only penetrate the subfloor 5/16″ (for 5/8″ flooring) or 1/2″ (for 3/8″ flooring), and when used over the previously wetted OSB subflooring, they have very little to hold on to.

Wider Planks
The trends have been continuing to move toward wider planks. Wide plank installation poses new challenges. Wider planks result in fewer fasteners per square foot. Consider how many fasteners are in any given square foot of a properly installed engineered wood floor that has been nailed at 3″-4″ intervals:

  • between 12 and 16 fasteners per square foot on a 3″ wide plank;
  • between 6 and 8 fasteners per square foot on a 6″ wide plank; and
  • between 3 and 4 fasteners per square foot on a 12″ wide plank.

More fasteners are not always feasible. Alternative installation methods such as full-spread or glue-assisted installations are sometimes a good alternative option. These options over wood subfloors are only acceptable when moisture is 100 percent controlled from below the flooring system. Further discussion on this topic is one for another article.

Overdriven/Underdriven Fasteners
It is not uncommon for a crew to use an undersized compressor or to have several nailers running off one compressor at a job site. Without an individual regulator on each hose, the compressor will not be able to deliver air pressure consistently to each nailer throughout the installation. To compensate for this, some crews will turn the PSI up on their compressor. This causes too much air being delivered to the nailer when the tank is full, resulting in overdriven fasteners, and often accompanying cracked tongues.

When the tank is depleted of air, the compressor cannot deliver enough air to the nailer, resulting in underdriven fasteners. This causes staples or cleats that are not fully seated into the tongue of the flooring product. When either of these occurs sporadically throughout the installation of the flooring system, it is not uncommon to hear crackling and popping from the improperly driven fasteners.

Trigger-Activated Flooring Nailers
When using trigger-activated flooring nailers (where it is common to use the gun while out in front of the floor is installed, rather than standing on top of the floor), it is common for flooring installers to use the pneumatic pressure of the gun to draw the boards tightly together, rather than use a mallet or tapping block. This action, accompanied by limited to no downward pressure being applied to the plank, can result in a blow-out.

Tyler Powell from Powernail adds, “Many times, installers will not properly adjust their tool to accommodate the exact thickness of engineered flooring products. In that instance, a nailer or stapler will not drive the flooring fastener at the proper angle through the nail pocket and into the subfloor. That incorrect angle can be the cause of blow-out on the underside of the floorboard and lead to squeaking, popping, or crunching. A few minutes spent properly adjusting your nailer is a fairly cheap premium for call-back insurance.”

Anytime the floor is not driven tightly together or tightly to the subfloor, it may result in a noisy floor after the entire unit has been installed.

Installation Methods Over Acoustical Underlayment Material
A relatively new cause for noisy floors is related to installation methods over acoustical underlayment material. Acoustical underlayment materials commonly used under wood flooring systems include cork, foam, rubber, and many recycled cellulose fiber pads. Proper installation methods over these underlayment materials may include floating, glue-down, or nail-down over a floated wood subfloor.

Some manufacturers promote nailing directly through these acoustical underlayment materials as an appropriate installation method. This is not an appropriate installation method. The transmission of sound becomes compromised as soon as any fastener penetrates the acoustical underlayment material, resulting in a useless sound control system. Not only is the acoustical membrane compromised, but also several other noises are then produced from within the system. Here are some reasons this method is a common cause for squeaking, popping, and crunching sounds:

  • None of these materials are designed to hold a fastener. The fastener withdrawal resistance becomes greatly diminished and will result in a loose flooring system.
  • The thickness of these pads also minimizes the actual subfloor
    fastener penetration.
  • The density of these underlayments will compress when a fastener is driven through, driving the flooring tight to the substrate. This forces the flooring out of a flat pane and results in vertical movement within the flooring system.
  • The creation of pivot points/anchors within the flooring system.

Anytime the floor is not driven tightly to the subfloor, it will result in a noisy flooring system after the entire unit has been installed. Keep in mind, most manufacturers who promote these installation methods do not warranty against squeaking.

In Conclusion
Many of the causes of squeaking, popping, and crunching sounds that come from the flooring system are avoidable. It takes combined collaboration between the builder, the end-user, the involved manufacturers, and the flooring professional to be able to mitigate the causes.

There are several ways to address noisy floors in substrate systems, as well as many options to address noises originating from installed wood flooring systems. However, if the flooring system exhibits no vertical movement that affects the in-use function of the installed wood floor, the noises are likely something that is considered perfectly normal.